– RAF
Floor Mounted Inverter Heat Pump
– RAF
Floor Mounted Inverter Heat Pump
A system for all seasons, floor mount heat pumps are an effective choice when wall space is limited.
– Fresher Air with Hitachi Heat Pumps
The Wasabi Nano Titanium filter uses particles of Wasabi root to remove up to 99% of the most common mites, bacteria and allergens, as well as bad odours commonly found in Heat Pumps.
You Heat Pumps filter is packed with a hybrid coating of Nano Titanium and Wasabi solution which provides a powerful antibacterial, anti-mould, anti-allergen and deodorising effect, reducing bacteria and allergen levels.
You Heat Pumps filter is packed with a hybrid coating of Nano Titanium and Wasabi solution which provides a powerful antibacterial, anti-mould, anti-allergen and deodorising effect, reducing bacteria and allergen levels.
– Industry leading 6 Year Heat Pump Warranty
An industry leading 6 year parts and labour warranty covers your Floor Mounted Hitachi heat pumps for your home and office. This offers peace of mind that your heat pump will perform year after year.
– Online Heat Pump Selection Tool
Use our online Heat Pump Selection tool to find the heat pump that best suits your requirements.
Evaluating where you live in NZ and the size of your room will give a general idea of the correct heat pump required. You can then request a free home assessment or call us direct.
Evaluating where you live in NZ and the size of your room will give a general idea of the correct heat pump required. You can then request a free home assessment or call us direct.
– Superior Technology from the Ground Up.
Compact and extremely efficient, Hitachi's inverter floor Heat Pump are ideal if you want to position your Heat Pump floor level - either by preference or because you wish to avoid using a wall-mounted unit on an apartment common wall.
Floor Heat Pumps efficiently distribute air right across your entire room.
The Power Active Module (PAM) Inverter system minimises power losses and ensures Heat Pump efficiency even when temperatures drop below -15°C. With the Twin Inverter rotary compressor, you can be assured of a smoother quieter Heat Pump operation.
Floor Heat Pumps efficiently distribute air right across your entire room.
The Power Active Module (PAM) Inverter system minimises power losses and ensures Heat Pump efficiency even when temperatures drop below -15°C. With the Twin Inverter rotary compressor, you can be assured of a smoother quieter Heat Pump operation.
– Model
Model
RAF-35NXA1/RAC-35NXA1 | RAF-50NXA1/RAC-50NXA1 |
---|
Capacity | Nominal Cooling | kW |
Nominal Heating | kW |
Capacity (Range) | Cooling | kW |
Heating | kW |
Airflow | l/sec |
Energy Efficiency | EER / AEER Cooling | |
COP / ACOP Heating | ||
Star Rating Cooling | ||
Star Rating Heating |
Noise Levels (dB(A)) Cooling | Indoor Unit | Hi/Med/Low/Sleep |
Outdoor Unit | Cooling/Heating |
Dimensions (mm) | Indoor Unit | (WxHxD) |
Outdoor Unit | (WxHxD) |
Weights (kg) | Indoor / Outdoor |
Operating Range | Outdoor Op. Temp. | Cooling |
Outdoor Op. Temp. | Heating |
Refrigerant Type |
Pipe Sizes (mm) | ||
Refrig Pipe charge | ||
Min / Max Pipe Lgth / Lift (m) |
Power | Power Supply | |
Run Amps at 230v | Cooling / Heating | |
Power Supply To | ||
Rec. Circuit Breaker (A) | ||
Interconnecting Wire |
3.5 |
4.2 |
1.1-4.2 |
1.1-5.2 |
167 |
3.80/3.74 |
3.95/3.89 |
2.5 |
3 |
42/35/29/25 |
47/49 |
760 x 600 x 235 |
841 x 548 x 335 |
14 / 36 |
R410A |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
4.80 / 4.90 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |
5 |
6 |
1.1-5.2 |
2.2-7.3 |
180 |
3.33/3.29 |
3.87/3.83 |
2 |
3 |
46/37/30/25 |
52/52 |
760 x 600 x 235 |
887 x 600 x 345 |
14 / 40 |
R410A |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
6.20 / 7.00 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |
– Documentation
Manuals, brochures and other product literature. If you need any more information, please get in touch.
– Model
Model
RAF-35NXA1/RAC-35NXA1 | RAF-50NXA1/RAC-50NXA1 |
---|
Capacity | Nominal Cooling | kW |
Nominal Heating | kW |
Capacity (Range) | Cooling | kW |
Heating | kW |
Airflow | l/sec |
Energy Efficiency | EER / AEER Cooling | |
COP / ACOP Heating | ||
Star Rating Cooling | ||
Star Rating Heating |
Noise Levels (dB(A)) Cooling | Indoor Unit | Hi/Med/Low/Sleep |
Outdoor Unit | Cooling/Heating |
Dimensions (mm) | Indoor Unit | (WxHxD) |
Outdoor Unit | (WxHxD) |
Weights (kg) | Indoor / Outdoor |
Operating Range | Outdoor Op. Temp. | Cooling |
Outdoor Op. Temp. | Heating |
Refrigerant Type |
Pipe Sizes (mm) | ||
Refrig Pipe charge | ||
Min / Max Pipe Lgth / Lift (m) |
Power | Power Supply | |
Run Amps at 230v | Cooling / Heating | |
Power Supply To | ||
Rec. Circuit Breaker (A) | ||
Interconnecting Wire |
3.5 |
4.2 |
1.1-4.2 |
1.1-5.2 |
167 |
3.80/3.74 |
3.95/3.89 |
2.5 |
3 |
42/35/29/25 |
47/49 |
760 x 600 x 235 |
841 x 548 x 335 |
14 / 36 |
R410A |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
4.80 / 4.90 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |
5 |
6 |
1.1-5.2 |
2.2-7.3 |
180 |
3.33/3.29 |
3.87/3.83 |
2 |
3 |
46/37/30/25 |
52/52 |
760 x 600 x 235 |
887 x 600 x 345 |
14 / 40 |
R410A |
20 |
3 / 20 / 10 |
230 - 240 Volt / 50 Hz / 1 Phase |
6.20 / 7.00 |
Outdoor Unit |
16 |
1.5mm 2 Core + E |